CONFIDENTIAL Listing of CAP1000 GN6 Parameters

Parameter

Setting

Value

Explanation

0000

00100001

bit 5

= 1 metric/inch option

 

 

 

= 0 metric only

0001

00000000

 

 

0002

00100000

 

 

0003

10001000

bit 4

= 1 runtime clock displayed.

 

 

 

= 0 runtime clock not displayed.

 

 

 

Note: Clock data in parameters 57, 58, 59 - clock data clears if machine on less than 6 minutes.

 

 

bit 7

= 1 P.C. parameters displayed.

 

 

 

= 0 P.C. parameters not displayed.

0004

00000000

 

 

0005

0000000

   

0006

10010001

bit 5

= 0 ignore servo off signal.

 

 

 

= 1 recognizes servo off signal.

 

 

bit 6

= 0 normal handling of M30 code.

0007

11100010

bit 7

= 0 automatic drift compensation off.

 

 

bit 5

= 1 reference point return uses special G codes.

0008

00001001

bit 3

= 0 powers up in G91 mode

 

 

 

= 1 powers up in G90 mode

 

 

bit 7

= 0 LF CR CR codes are punched as EOB in ISO code

 

 

 

= 1 LF codes are punched as EOB in ISO code

0010

00000010

 

 

0011

11000000

bit 5

= 0 decelerate when limit switch opens.

 

 

 

= 1 decelerate when limit switch closes.

0013

00010000

 

 

0014

00010001

 

X axis DMR (detect multiplying ratio - limit 10,000 counts)

0015

00010001

 

Y axis DMR (detect multiplying ratio - limit 10,000 counts)

0018

00000011

 

 

0019

10100001

 

sets time to respond to M code

0020

00000011

 

 

0021

00011011

 

 

0027

4

 

X axis CMR (command multiplying ratio)

0028

4

 

Y axis CMR (command multiplying ratio)

0057

-----

 

runtime clock - hours

0058

-----

 

runtime clock - minutes

0059

-----

 

runtime clock - seconds

 

 

 

Note#1: Param. 3.4 permits display of clock

 

 

 

Note#2: Reading clears if machine not on a minimum of 6 minutes

0060

0

 

clutch off timer for nibble (TPF 10)

0061

0

 

clutch on signal off time (*PE to PFB)

0062

0

 

 

0070

100

 

X axis - in position deadband

0071

100

 

Y axis - in position deadband

0074

500

 

X axis - max following error when stopped

0075

500

 

Y axis - max following error when stopped

0078

3000

 

X axis - max following error when moving

0079

3000

 

Y axis - max following error when moving

0082

-----

 

X axis grid shift (home position offset) - varies

0083

-----

 

Y axis grid shift (home position offset) - varies

 

 

 

Note: Offsets measured in detect units. 1 detect unit =.0005 inch. Lower number moves hole closer to edge of sheet - must power down and back up to register change.

0086

3584

 

X axis servo loop gain multiplier

0087

3584

 

Y axis servo loop gain multiplier

0091

10

 

 

0092

2000

 

 

0093

2000

 

 

0096

50

 

X axis accel/decel time constant in auto

0097

50

 

Y axis accel/decel time constant in auto

0100

40

 

X axis accel/decel time constant in manual

0101

40

 

Y axis accel/decel time constant in manual

0106

3000

 

max feedrate

0107

200

 

 

0114

400

 

slow speed during reference, 500 max. Too slow and axis won’t reference ( 91 alarm)

0128

400

 

 

0129

410

 

 

0143

126

 

X minus software limit

0144

501

 

Y minus software limit

0147

-42751

 

X plus software limit.

0148

-40501

 

Y plus software limit.

0167

100

 

accel/decel ramp data (inch)

0168

500

 

accel/decel ramp data (inch)

0169

1000

 

accel/decel ramp data (inch)

0170

2000

 

accel/decel ramp data (inch)

0171

3000

 

accel/decel ramp data (inch)

0172

4000

 

accel/decel ramp data (inch)

0180-0299

not used

 

 

0300

00010000

   

0301

00000010

 

 

0308

01000000

 

 

0309

00000011

bit 0

= 1 automatic coordinate system is effective for X axis

 

 

bit 1

= 1 automatic coordinate system is effective for Y axis

0310

00000101

 

Characteristics for 0310 to 0313

0311

00100101

bit 5

= 1 DC1 - DC4 codes not used.

0312

00000101

 

= 0 DC1 - DC4 codes used.

0313

00000101

bit 4

= 1 2 stop bits

 

 

 

= 0 1 stop bit

 

 

bit 0-3

set baud rate for 1/0 interface, see parameters 0340 -341

Baud

3

2

1

0

50

0

0

0

0

100

0

0

0

1

110

0

0

1

0

150

0

0

1

1

200

0

1

0

0

300

0

1

0

1

600

0

1

1

0

1200

0

1

1

1

2400

1

0

0

0

4800

1

0

0

1

9600

1

0

1

0

0317

00001110

 

 

0318

11000000

bit 5

= 1 display of macro contents suppressed while running program

 

 

 

= 0 macro contents displayed while running program

 

.

bit 6

= 1 single stepping through macro disabled

 

 

 

= 0 single stepping enabled

 

 

bit 7

= 1 programs in 9000 series are locked, cannot be loaded or edited

 

 

 

= 0 programs in 9000 series can be loaded or edited.

0319

10000001

bit 7

same as param. 0318 for 8000 series programs

0324

82

 

 custom macro call

0325

83

 

 custom macro call

0326

84

 

 custom macro call

0340

2

 

Input Device

 

 

 

0 = tape reader

 

 

 

1 = ASR-43 (set baud in param. 310)

 

 

 

2 = RS-232 (set baud in param. 311)

 

 

 

3 = RS-232 (set baud in param. 312)

 

 

 

4 = RS-232 (set baud in param. 313)

0341

2

 

Output Device

 

 

 

0 = Facit 4070 punch

 

 

 

1 = ASR-43 (set baud in param. 310)

 

 

 

2 = RS-232 (set baud in param. 311)

 

 

 

3 = RS-232 (set baud in param. 312)

 

 

 

4 = RS-232 (set baud in param. 313)

0375

104140

 

absolute preset at home for X axis (metric) 

0376

101600

 

absolute preset at home for Y axis (metric)

0377-0378

0

 

 

0379

48000

 

absolute preset at home for X axis (inch)

0380

38000

 

absolute preset at home for Y axis (inch)

0420

10001000

 

 

0421

00101000

   

0423

10000000

 

 

0425

81

 

sets M81 code (post-punch delay on)

0426

82

 

sets M82 code (post-punch delay off)

0427

3

 

 

0428

4

 

 

0429

12

 

M code for nibble start (coordinate nibble)

0430

13

 

M code for nibble end (coordinate nibble)

0436

-----

 

delay from punch end switch to clutch dump – varies

0437

210

 

block processing delay 

0438

50

 

delay before punch in milliseconds

0439

100

 

M81 post-punch delay time in milliseconds

0443

----

 

delay from clutch dump to brake on – varies

0450

-50

 

 

0451

-50

 

 

0452

3500

 

X axis position loop gain

0453

3500

 

Y axis position loop gain

0454

1

 

T axis position loop gain

0456

1000

 

X rapid traverse rate (manual)

0457

1000

 

Y rapid traverse rate (manual)

0460

40

 

jog ramp parameters

0461

40

 

jog ramp parameters

0468

9999

 

max. nibble bite for G68/G69 metric 1-9999 (.01 mm)

0469

9999

 

max. Nibble bite for G68/G69 inch 1-9999 (.001")

0470

9999

 

maximum nibble feedrate (Q) - metric value

0471

140

 

maximum nibble feedrate (Q) - inch value

0472

400

 

accel/decel ramp data (metric)

0473

1270

 

accel/decel ramp data (metric)

0474

2540

 

accel/decel ramp data (metric)

0475

5080

 

accel/decel ramp data (metric)

0476

7620

 

accel/decel ramp data (metric)

0477

10160

 

accel/decel ramp data (metric)

0478-0479

500

 

rapid traverse speeds X axis

0480-0484

2000

 

rapid traverse speeds X axis

0485

40

 

0 - .2 inch ramp

0486

40

 

.2 - .5 inch ramp

0487

40

 

.5 - 1 inch ramp

0488

80

 

1 - 3 inch ramp

0489

80

 

3 - 5 inch ramp

0490

100

 

5 - 10 inch ramp

0491

150

 

10+ inch ramp

0492-0493

500

 

rapid traverse speeds Y axis

0494-0498

2000

 

rapid traverse speeds Y axis

0499

40

 

0 - .2 inch ramp

0500

40

 

.2 - .5 inch ramp

0501

40

 

.5 - 1 inch ramp

0502

80

 

1 - 3 inch ramp

0503

80

 

3 - 5 inch ramp

0504

100

 

5 - 10 inch ramp

0505

100

 

10+ inch ramp

0506

38

 

 

0507

10

 

10 = .010 inch, sets back-out of work clamps during prog. move will accept max. of 4.0 inches. Only active with G75, not 03/M04.

0512

-35

 

X axis punch anticipation

0513-0516

-40

 

X axis punch anticipation

0519

-35

 

Y axis punch anticipation

0520-0523

-40

 

Y axis punch anticipation

0540

1

 

T axis tool station at home

0541

20

 

number of turret stations

0542

1

 

T command for station 1

0543

2

 

T command for station 2

0544 to

3 to . . .

 

T command for station 3 to . . .

0561

20

 

T command for station 20

0917-0949

-----

 

counter for hits on each tool (0917=T01, 0918 = T02, etc.) – varies